Inventory Index  >  Boilers  >  Firetube Boilers

Used Cleaver Brooks CB-Packaged Firetube Boiler- 60 horse power. Model: CB200-60. Serial Number: L-69074. Input: 2,511,000 BTU/HR. Maximum pressure: 30HW psi. Fuel: Gas-Oil. Burner: 4A natural gas. Oil type: 4A. Oil supply: 0.3 gallons per minute [18 gallons per hour]. Power supply: 460 V, 7 amps, 60 Hz, 3 phase. Minimum circuit ampacity: 8 amps. Maximum circuit protection 28 amps. Cleaver Brooks Motor, 2 and 1-1/2 horse power, 3510/2850 rpm, 200-230/460-190/380 V, 5.8-5.4/2.7-5.0/2.5 amps, 60/50 Hz, 3 phase. A Firetube boiler is a cylindrical vessel, with the flame in the furnace and the combustion gases inside the tubes. The furnace and tubes are within a larger vessel containing the water which is converted to steam or hot water for process applications or hydronic comfort heating. Hot water is commonly used in heating applications with the boiler supplying water to the system at 180 F to 220 F. The operating pressure for hot water heating systems usually is 30 psig to 125 psig. Inlets: [2] 5 inches diameter flanged ports. Outlets: [1] 10 inches diameter flanged port, [1] 2 inches diameter NPT fitting [relief valve], [1] 1 inches diameter low water cut off port, [1] 2 inches diameter drain port. Overall dimensions: 10 feet 10 inches length x 6 feet 11 inches width x 6 feet 9 inches height.[h15].
Stock No: fpe_85.D001  |   Mfg: Cleaver Brooks  |   Model: CB200-60  |   S/N: fpe_L-69074

Used Cleaver Brooks CB-Packaged Firetube Boiler- 60 horse power. Model: CB-700-60. Serial Number: L-68819. Input: 2,511,000 BTU/HR. Burner: natural gas. Max. pressure: 30 HW psi. Tube material: carbon steel. Number of tubes: 62. Tube dimensions: 2-1/2 inches diameter x 7 feet 8 inches L. Heat transfer surface area: approx. 310.94 square feet Tube volume: 120 gal. Power supply: 480 V, 3.5 amps, 60 Hz, 3 phase. Minimum circuit capacity: 4.5 amps. Maximum rating circuit: 14 amps. Electrical blower motor- 2 horse power. A Firetube boiler is a cylindrical vessel, with the flame in the furnace and the combustion gases inside the tubes. The furnace and tubes are within a larger vessel containing the water which is converted to steam or hot water for process applications or hydronic comfort heating. Hot water is commonly used in heating applications with the boiler supplying water to the system at 180 F to 220 F. The operating pressure for hot water heating systems usually is 30 psig to 125 psig. Inlets: [2] 5 inches diameter flanged ports. Outlets: [1] 10 inches diameter flanged port, [1] 2 inches diameter NPT fitting [relief valve], [1] 1 inches diameter low water cut off port, [1] 2 inches diameter drain port. Overall dimensions: 10 feet 10 inches length x 5 feet width x 6 feet 9 inches height.(H15).
Stock No: fpe_250.170  |   Mfg: Cleaver Brooks  |   Model: CB-700-60  |   S/N: fpe_L-68819

Cleaver-Brooks Steam Boiler. Model: CBH743-60. Serial: L-25041. Input 2,520,000 BTU/HR natural gas, 150 lbs. psi, firetube type. (3) Honeywell Pressuretrol monitoring gauges. Date: 4/11/61. *Note: the boiler pressure tag was removed from the unit. Overall dimensions: 11 ft. 2 in. L x 6 ft. 5 in. W x 7 ft. 6 in. H.
Stock No: fpe_PMHT08.2a  |   Mfg: Cleaver Brooks  |   Model: CBH743-60  |   S/N: fpe_L-25041

Don't see what you're looking for? Let us know what you need.
© 2012 food-processing-equipment.biz - All Rights Reserved.