Inventory Index  >  Refrigeration  >  Ammonia Refrigeration  >  Ammonia Compressors  >  Ammonia Screw Compressors  >  Starters Motor Control Panels

Used 1995 Allen Bradley Motor Starter Control Panel. Serial Number: 7000092-001-95. Power supply: 4200v, 1200 amps [max], 60 Hz, 3 phase, full voltage, non-reversing. Allen-Bradley CENTERLINE motor control centers [MCCs] integrate control and power in one centralized package. The CENTERLINE offering includes AC drive units, solid-state motor controllers, smart overload relays, power monitors and PLC I/O chassis. Overall dimensions: 37 inches length x 26 inches width x 92 inches height.
Stock No: fpe_DTTC042.  |   Mfg: Allen-Bradley  |   Model:   |   S/N: fpe_7000092-001-95

(2) Eaton SVX 9000 Adjustable Frequency Drive Starters. Serial No: 12784850 & 12784861. Cat No: SVX80014AAP1P3. G.O. & Style: SYW99265-001. Nominal HP: 800. IL Overload : 1.10. Software Code: 0. Date Code 071210. Enclosure: Oversized Nema Type 1. Input: 480 VAC, 3 Ph, 550/60 HZ, 930 A RMS. Output: 0 to 480 VAC, 3 Ph, 1 to 500 HZ, 960 A RMS. Overall dimensions: 60 ft. W x 2 ft. 6 in. L x 8 ft. 3 in. H.
Stock No: fpe_NTSD04B  |   Mfg: Eaton  |   Model: SVX9000  |   S/N: fpe_12784850 & 12784861

Used 1998 Cutler-Hammer Ampgard Medium Voltage Motor Starter Control Panel . Unit: 1C. Cat. No: S210SBE 12/98. Order No: HTA88488-001. Ref: 98-TA488S10. Power supply: 500 horse power 4160 V, 79.9 FLA, 1.25 SF, 60 Hz. Each roll out Ampgard motor starter [controller] consists of one non load-break isolating switch, one or more Type SLS vacuum-break contactors, current-limiting fuses, a set of current transformers, and some form of overload protection. The controller is designed to start, stop and protect a three-phase medium-voltage motor or may also be used to switch transformer windings or other medium voltage loads. These controllers are configured for full-voltage, non reversing, single speed applications. Overall dimensions: 36 inches length x 34 inches width x 111 inches height.[h11]
Stock No: fpe_DTTC027  |   Mfg: Cutler Hammer  |   Model:   |   S/N: fpe_

Used Each Ampgard motor starter [controller] consists of one non load-break isolating switch, one or more Type SLS vacuum-break contactors, current-limiting fuses, a set of current transformers, and some form of overload protection. The controller is designed to start, stop and protect a three-phase medium-voltage motor or may also be used to switch transformer windings or other medium voltage loads. These controllers are configured for full-voltage applications. Westinghouse IQ-2000 Variable Frequency Inverter provides complete circuitry protection against abnormal operations such as overload, Inductive type loads, short-circuit, and AC Input Over-Voltage.
Stock No: fpe_DTTC031.  |   Mfg: Westinghouse  |   Model:   |   S/N: fpe_

Used Westinghouse Ampgard Motor Starter Control Panel. Ref. No's: AT-72960-1 and V202J4G. Power supply: 400 horse power, 4160 V, 60 Hz. Westinghouse IQ-2000 Variable Frequency Inverter. Each Ampgard motor starter [controller] consists of one non load-break isolating switch, one or more Type SLS vacuum-break contactors, current-limiting fuses, a set of current transformers, and some form of overload protection. The controller is designed to start, stop and protect a three-phase medium-voltage motor or may also be used to switch transformer windings or other medium voltage loads. These controllers are configured for full-voltage applications. Westinghouse IQ-2000 Variable Frequency Inverter provides complete circuitry protection against abnormal operations such as overload, Inductive type loads, short-circuit, and AC Input Over-Voltage. Overall dimensions: 37 inches length x 37 inches width x 103 inches height.
Stock No: fpe_DTTC033.  |   Mfg: Westinghouse  |   Model:   |   S/N: fpe_

Used Westinghouse Ampgard Medium Voltage Motor Starter Control Panel. Ref. No's: AR-11125-3 and V202R4G. Dwg: 3D52933, 3D52934, 3D52932. Power supply: 250 horse power, 4160v, 60 Hz. Westinghouse IQ-2000 Variable Frequency Inverter. Each Ampgard motor starter [controller] consists of one non load-break isolating switch, one or more Type SLS vacuum-break contactors, current-limiting fuses, a set of current transformers, and overload protection. The controller is designed to start, stop and protect a three-phase medium-voltage motor or may also be used to switch transformer windings or other medium voltage loads. These controllers are configured for full-voltage applications. Westinghouse IQ-2000 Variable Frequency Inverter provides complete circuitry protection against abnormal operations such as overload, inductive type loads, short-circuit, and AC Input Over-Voltage. Overall dimensions: 42 inches length x 41 inches width x 102 inches height.
Stock No: fpe_DTTC034.  |   Mfg: Westinghouse  |   Model:   |   S/N: fpe_

Used Motor Starter Control Center. This motor starter control center provides starters for different horse power rated motors as follows: [1] 200 horse power, [1] 120 horse power, [2] 50 horse power, [1] 20 horse power, [4] 7 horse power, [5] 5 horse power, [4] 2 horse power, [1] 1 horse power, and [2] 1.0 horse power motors. These starters are distributed among 3 main sections that make the whole center. Section 1 provides: [1] 200 horse power starter. Section 2 provides: [1] 120 horse power, [2] 7 horse power, [4] 2 horse power, [1] 1 horse power, and [2] 1.0 horse power. Section 3 provides: [2] 50 horse power, [1] 20 horse power, [2] 7 horse power, [5] 5 horse power. Supply power required: 460 V, 60 Hz, 3 phase. Overall dimensions: 15 feet length x 1 feet 9 inches width x 7 feet 6 inches H.[BG].
Stock No: fpe_PCNY09  |   Mfg: Siemens  |   Model:   |   S/N: fpe_

Stock No: fpe_TSRC01.25  |   Mfg: Allen-Bradley  |   Model: 150-F251NBD  |   S/N: fpe_

Don't see what you're looking for? Let us know what you need.